ADVIA 1650 Chemistry System

Power - Reliability - Expertise

Microvolume technologyThe ADVIA 1650 has minimal requirements for sample volume (as low as 2 L/test), reagent consumption (as low as 80 L/test) and water consumption (25 L/hour) - thus maximizing management efficiency.

Outstanding productivityA rapid, 3-second cycle and system throughput of up to 1650 tests/hour provide powerful high-speed performance, ensure workflow efficiency through peak workloads. Optional universal rack handler facilitates continuous sample feeding for further productivity gains.

Unparalleled walkaway capabilityOn-board capacity of 200 samples and 32,000 tests - plus our exclusive Sample Saver Technology for automatic repeat, dilution and reflex testing without operator intervention - optimizes walkaway time, frees you to work on additional tasks.

Expertise in automationFor 50 years we have been recognized for our innovation - just as clinical chemistry has been recognized as the driver of automation. The tradition continues. The ADVIA 1650 can be integrated with other testing disciplines via the ADVIA WorkCell or ADVIA LabCell automated sample transportation systems.

Technical specifications

Overview
Type of System Random, continuous access, batch, discrete processing
Throughput Rate 1650 tests/hour, 1200 tests/hour colorimetric, 450 tests/hour ISE
Methods Capacity Onboard 49 including 3 ISE
Sample Handling
Sample Tubes 2mL, 5 mL, 7 mL, 10 mL sample cups, microcontainer tubes
Sample Tray 84 samples, positive sample identification
Sample Rack Handler (optional) Universal 5-position rack, 425 total Onboard sample capacity; continous feed
Sample Integrity Check Qualitative check for Hemolysis, Lipemia and Icterus
STAT Positions 84, not dedicated
Bar Codes 2 of 5, code 39, code 128, Codabar (NW7)
Auto-repeat Automatic repeat testing from the retained pre-diluted sample or original sample
Auto-dilution Automatic dilution from retained pre-diluted sample
Auto-reflex Testing Automatic ability to perform 3 additional tests based on results of first test
Primary Probe Liquid Level Sensing, Crash Protection, Clot/Clog Detection and Short Sample Detection
Secondary Probe Liquid Level Sensing
Microvolume Technology
Automatic Sample Pre-dilution Samples diluted 1:5 (30 L sample + 120 L saline generates up to 15 test results)
pre-dilution tray 120 dilution cups
Original Sample Volume 2 to 30 L; average of 2-3 L per test
Average Reagent Volume 80-120 L per test
Storage Capacity Onboard 20,000 tests average; 32,200 tests maximum
Reaction Area
Reaction Tray 221 reusable plastic cuvettes
Cuvette Optical Path Length 10 mm
Reaction Bath Inert fluorocarbon oil circulation system, 37C
Photometer 14 fixed wavelengths (340, 410, 451, 478, 505, 545, 571, 596, 658, 694, 751, 805, 845 and 884)
Light Source 12V, 50W halogen lamp, cooled by forced water circulation
Assay Methods Endpoint, rate reaction, 2-point rate, multi-point homogeneous immunoassay
Reaction Times 3, 4, 5, 10, 15 and 20 minutes
Automatic Correction Serum blank, cell blank, measurement point change, sample volume change in reassay
Point Forwarding Automatically extends linear1ity over assay-range samples
Reagent Handling
Reagent Tray 2 trays, 50 positions each, refrigerated
Reagent Capacity Onboard 46 colorimetric methods
Dispensing System 2 probes with Liquid Level Sensing
Reagent Wedges 20, 40, 70 mL barcode labeled wedges
Onboard Stability Up to 60 days
Reagent Inventory Management Tracks tests remaining, lot number, Onboard stability and expiration date
Reagent Dilutions Capability to dilute concentrated reagents Onboard
Open System Capibility
Channels 100 channels; includes user-defined applications
Bayer 3rd Party Applications Varies by country, can be configured on system
ISE
ISE Indirect simultaneous measurement of Na+, K+, Cl-
Sample Volume 28 L for all three tests
Priming Automatic priming cycle
Electrode Shelf Life 30,000 Samples
Throughput Rate 450 tests/hour; 150 tubes/hour
Calibration/QC
Calibration Interval Up to 60 days
Auto-Calibration/QC User-defined time interval or with new reagent container
View Calibration/QC Data Graphical display of calibration curve and QC; real-time QC
Calibration/Control Tray 61 refrigerated positions for calibrators, controls and diluents
Data Management
Computer Windows NT, flat panel display
SystemDocumentation Operator manual and method sheets on-line
Host Interface RS 232C bidirectional
Data Storage 70,000 patient samples
OnboardMaintenance Logs Schedule and monitor routine maintenance activities via software
Host Query ASCII; system requests work-order or batch of work-orders from host
General Specifications
Power Requirements 100/110/115/200/220/230 V +/10%, 26 A, 50/60 Hz, 3 KVA
Water Requirements Deionized water from a non-pressurized water reservoir. Maximum consumption: 6.8 gallons per hour (25 liters per hour)
Drain Requirements Minimum of 6.8 gallons per hour (25 liters per hour)
Dimensions ADVIA 1650:44.45 (h) x 58.27 (w) x 34.13 (d) in.,
112.9 (h) x 148.0 (w) x 86.7 (d) cm.ADVIA Rack Handler:
37 (h) x 29 (w) x 41 (d) in.,86.4 (h) x 73.7 (w) x 104.1 (d) cm.
Weight ADVIA 1650: 1,178 lbs. (534.3 kg)Universal Rack Handler 178 lbs. (80.7 kg)
Compliance UL, cUL, CE
Noise Specifications Average with top cover closed 55.91 db
Average Heat Output 4,643 Btu/hr.
Operating Temperature Range 18C - 30C/64F - 86F
Ambient Humidity 40% - 70%